Users Online: 187 Home Print this page Email this page Small font sizeDefault font sizeIncrease font size  
Home | About us | Editorial board | Search | Ahead of print | Current issue | Archives | Submit article | Instructions | Subscribe | Contacts | Login 

 
ORIGINAL ARTICLE
Year : 2021  |  Volume : 37  |  Issue : 2  |  Page : 266-271

A randomized control led study comparing CMAC video laryngoscope and Macintosh laryngoscope for insertion of double lumen tube in patients undergoing elective thoracotomy


1 Department of Anaesthesia, Christian Medical College, Vellore, Tamil Nadu, India
2 Department of CTVS, Christian Medical College, Vellore, Tamil Nadu, India
3 Department of Biostatistics, Christian Medical College, Vellore, Tamil Nadu, India

Correspondence Address:
Dr. Raj Sahajanandan
Department of Anaesthesia, Ida Scudder Road Christian Medical College, Vellore - 632 002, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/joacp.JOACP_79_20

Rights and Permissions

Background and Aims: Double lumen tube (DLT) insertion for isolation of lung during thoracic surgery is challenging and is associated with considerable airway trauma. The advent of video laryngoscopy has revolutionized the management of difficult airway. Use of video laryngoscopy may reduce the time to intubate for DLTs even in patients with normal airway. Material and Methods: A total of 87 ASA 1–3 adults, scheduled to undergo elective thoracotomy, requiring a DLT were randomly allocated to videolaryngoscope (CMAC) arm or Macintosh laryngoscope arm. It was on open label study, and only the patient was blinded. The primary objective of this study was to compare the mean time taken for DLT intubation with CMAC (Mac 3) and Macintosh laryngoscope blade and the secondary objectives included the hemodynamic response to intubation, the level of difficulty using the intubation difficulty scale (IDS), and complications associated with intubation. Data was analysed using the statistical software SPSS (version 18.0). Results: The time taken for intubation was not significantly different (42.8 ± 14.8 s for CMAC and 42.5 ± 11.5 s for Macintosh laryngoscope P -0.908). The CMAC video laryngoscope was associated with an improved laryngoscopy grade (Grade I in 81.8% with CMAC and in 46.5% with Macintosh), less pressure applied on the tongue, and less external laryngeal pressure required. Hemodynamic responses to intubation were similar in both groups. Conclusion: Macintosh blade is as good as CMAC (mac 3) blade to facilitate DLT intubation in adult patients with no anticipated airway difficulty, however CMAC was superior as it offers better laryngoscopic view, needed less force, and fewer external laryngeal manipulations.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed254    
    Printed20    
    Emailed0    
    PDF Downloaded29    
    Comments [Add]    
    Cited by others 1    

Recommend this journal